Warning Icon

For other alternatives, please contact us for more information.

0 Alternative products available

CTX192126T-DS-43 | E14F60P09

Twin Triplexer, PCS/AWS/WCS-BRS, DC Sense

Find a Partner
Specifications
Finish making your selections or clear them to view relevant specifications.
Features and Benefits
  • BTS-to-feeder and feeder-to-antenna application
  • Automatic dc switching with dc sense
  • DC Load Sense in Feeder-to-Antenna applications
  • Convertible mounting brackets
  • New 4.3-10 connectors for improved PIM performance and size reduction

Product Classification

Product Type Triplexer

General Specifications

Color Gray
Common Port Label Common
Mounting Pole | Wall
Mounting Pipe Hardware Band clamps (2)
RF Connector Interface 4.3-10 Female
RF Connector Interface Body Style Long neck

Dimensions

Height 147 mm | 5.787 in
Width 177 mm | 6.969 in
Depth 105 mm | 4.134 in
Ground Screw Diameter 6 mm | 0.236 in
Mounting Pipe Diameter Range 40–160 mm

Outline Drawing

Click on image to enlarge.

Electrical Specifications

Impedance 50 ohm
License Band, Band Pass AWS 1700 | PCS 1900 | TDD 1900 | TDD 2000 | WCS 2300

Electrical Specifications, dc Power/Alarm

dc/AISG Pass-through Method Auto sensing
dc/AISG Pass-through Path See logic table
Lightning Surge Current 10 kA
Lightning Surge Current Waveform 8/20 waveform
Operating Current at Voltage 10 mA @ 12 Vdc
Voltage 7–30 Vdc

Electrical Specifications, AISG

AISG Carrier 2176 KHz ± 100 ppm
Insertion Loss, maximum 1 dB
Return Loss, minimum 15 dB

Electrical Specifications

Sub-module 1 1 1
Branch 1 2 3
Port Designation 1695-1780 & 2110-2200 1850-1995 2305-2690
License Band AWS 1700, Band Pass PCS 1900, Band Pass WCS 2300, Band Pass

Electrical Specifications, Band Pass

Frequency Range, MHz 1695–1780
2110–2200
1850-1995 2305–2690
Insertion Loss, typical, dB 0.30 0.30 0.30
Total Group Delay, maximum, ns 25 20 25
Total Group Delay, typical, ns 19 18 12
Return Loss, typical, dB 23 23 23
Isolation, typical, dB 53 53 53
Input Power, RMS, maximum, W 200 200 200
Input Power, PEP, maximum, W 2,000 2,000 2,000
3rd Order PIM, typical, dBc -161 -161
3rd Order PIM Test Method 2 x 20 W CW tones 2 x 20 W CW tones
Higher Order PIM, typical, dBc -161
Higher Order PIM Test Method 2 x 20 W CW tones

Block Diagram

Click on image to enlarge.

Logic Table

Click on image to enlarge.

Mechanical Specifications

Wind Loading @ Velocity, frontal 13.0 N @ 150 km/h (2.9 lbf @ 150 km/h)
Wind Loading @ Velocity, lateral 13.0 N @ 150 km/h (2.9 lbf @ 150 km/h)

Environmental Specifications

Operating Temperature -40 °C to +65 °C (-40 °F to +149 °F)
Corrosion Test Method IEC 60068-2-11, 30 days
Ingress Protection Test Method IEC 60529:2001, IP67

Packaging and Weights

Included Mounting hardware
Volume 2.7 L
Weight, net 4.2 kg | 9.259 lb

Product Classification

Product Type Triplexer

General Specifications

Color Gray
Common Port Label Common
Mounting Pole | Wall
Mounting Pipe Hardware Band clamps (2)
RF Connector Interface 4.3-10 Female
RF Connector Interface Body Style Long neck

Dimensions

Height 147 mm | 5.787 in
Width 177 mm | 6.969 in
Depth 105 mm | 4.134 in
Ground Screw Diameter 6 mm | 0.236 in
Mounting Pipe Diameter Range 40–160 mm

Electrical Specifications

Impedance 50 ohm
License Band, Band Pass AWS 1700 | PCS 1900 | TDD 1900 | TDD 2000 | WCS 2300

Electrical Specifications, dc Power/Alarm

dc/AISG Pass-through Method Auto sensing
dc/AISG Pass-through Path See logic table
Lightning Surge Current 10 kA
Lightning Surge Current Waveform 8/20 waveform
Operating Current at Voltage 10 mA @ 12 Vdc
Voltage 7–30 Vdc

Electrical Specifications, AISG

AISG Carrier 2176 KHz ± 100 ppm
Insertion Loss, maximum 1 dB
Return Loss, minimum 15 dB

Electrical Specifications

Sub-module 1 1 1
Branch 1 2 3
Port Designation 1695-1780 & 2110-2200 1850-1995 2305-2690
License Band AWS 1700, Band Pass PCS 1900, Band Pass WCS 2300, Band Pass

Electrical Specifications, Band Pass

Frequency Range, MHz 1695–1780; 2110–2200 1850-1995 2305–2690
Insertion Loss, typical, dB 0.30 0.30 0.30
Total Group Delay, maximum, ns 25 20 25
Total Group Delay, typical, ns 19 18 12
Return Loss, typical, dB 23 23 23
Isolation, typical, dB 53 53 53
Input Power, RMS, maximum, W 200 200 200
Input Power, PEP, maximum, W 2,000 2,000 2,000
3rd Order PIM, typical, dBc -161 -161
3rd Order PIM Test Method 2 x 20 W CW tones 2 x 20 W CW tones
Higher Order PIM, typical, dBc -161
Higher Order PIM Test Method 2 x 20 W CW tones

Mechanical Specifications

Wind Loading @ Velocity, frontal 13.0 N @ 150 km/h (2.9 lbf @ 150 km/h)
Wind Loading @ Velocity, lateral 13.0 N @ 150 km/h (2.9 lbf @ 150 km/h)

Environmental Specifications

Operating Temperature -40 °C to +65 °C (-40 °F to +149 °F)
Corrosion Test Method IEC 60068-2-11, 30 days
Ingress Protection Test Method IEC 60529:2001, IP67

Packaging and Weights

Included Mounting hardware
Volume 2.7 L
Weight, net 4.2 kg | 9.259 lb
Click on image to enlarge.
Click on image to enlarge.
Click on image to enlarge.

Product Specification

Video

Filter Products – Designed for PIM Excellence
Filter Products – Designed for PIM Excellence

Product Specification

Video

Filter Products – Designed for PIM Excellence
Filter Products – Designed for PIM Excellence