Warning Icon
This product was discontinued on: March 31, 2023

For other alternatives, please contact us for more information.

0 Replacement products available

810009861/DB | C-008-DN-8W-M08YL/28G/AY/E

Base Product: C-DN

  • Available in:
  • Asia
  • Australia/New Zealand
  • EMEA

Fiber indoor/outdoor cable, LightScope ZWP® , Gel-filled loose tube, 8 fiber, Singlemode G.652.D, Meters jacket marking, Yellow jacket color, Eca flame rating

Specifications
Finish making your selections or clear them to view relevant specifications.

Product Classification

Regional Availability Asia | Australia/New Zealand | EMEA
Portfolio CommScope®
Product Type Fiber indoor/outdoor cable
Product Series C-DN

General Specifications

Cable Type Central loose tube
Construction Type Non-armored
Subunit Type Gel-filled
Jacket Color Yellow
Jacket Marking Meters
Fibers per Subunit, quantity 8
Total Fiber Count 8

Dimensions

Cable Length 1000 m | 3280.840 ft
Buffer Tube/Subunit Diameter 2.8 mm | 0.110 in
Diameter Over Jacket 6.4 mm | 0.252 in

Representative Image

Click on image to enlarge.

Mechanical Specifications

Minimum Bend Radius, loaded 130 mm | 5.118 in
Minimum Bend Radius, unloaded 75 mm | 2.953 in
Tensile Load, long term, maximum 400 N | 89.924 lbf
Tensile Load, short term, maximum 530 N | 119.149 lbf
Cable Crush Resistance, maximum 20 N/mm | 114.203 lb/in
Compression Test Method IEC 60794-1-2 E3
Impact 5 N-m | 44.254 in lb
Impact Test Method IEC 60794-1 E4

Optical Specifications

Fiber Type G.652.D | OS2

Optical Specifications, Wavelength Specific

Attenuation, maximum 0.35 dB/km @ 1,300 nm

Environmental Specifications

Installation temperature -20 °C to +70 °C (-4 °F to +158 °F)
Operating Temperature -20 °C to +70 °C (-4 °F to +158 °F)
Storage Temperature -20 °C to +70 °C (-4 °F to +158 °F)
EN50575 CPR Cable EuroClass Fire Performance Eca
Environmental Space Universal Low Smoke Zero Halogen (ULSZH)
Water Penetration 24 h

Environmental Test Specifications

Temperature Cycle -20 °C to +70 °C (-4 °F to +158 °F)
Temperature Cycle Test Method IEC 60794-1-2 F1

Packaging and Weights

Cable weight 44 kg/km | 29.567 lb/kft

Product Classification

Regional Availability Asia | Australia/New Zealand | EMEA
Portfolio CommScope®
Product Type Fiber indoor/outdoor cable
Product Series C-DN

General Specifications

Cable Type Central loose tube
Construction Type Non-armored
Subunit Type Gel-filled
Jacket Color Yellow
Jacket Marking Meters
Fibers per Subunit, quantity 8
Total Fiber Count 8

Dimensions

Cable Length 1000 m | 3280.840 ft
Buffer Tube/Subunit Diameter 2.8 mm | 0.110 in
Diameter Over Jacket 6.4 mm | 0.252 in

Mechanical Specifications

Minimum Bend Radius, loaded 130 mm | 5.118 in
Minimum Bend Radius, unloaded 75 mm | 2.953 in
Tensile Load, long term, maximum 400 N | 89.924 lbf
Tensile Load, short term, maximum 530 N | 119.149 lbf
Cable Crush Resistance, maximum 20 N/mm | 114.203 lb/in
Compression Test Method IEC 60794-1-2 E3
Impact 5 N-m | 44.254 in lb
Impact Test Method IEC 60794-1 E4

Optical Specifications

Fiber Type G.652.D | OS2

Optical Specifications, Wavelength Specific

Attenuation, maximum 0.35 dB/km @ 1,300 nm

Environmental Specifications

Installation temperature -20 °C to +70 °C (-4 °F to +158 °F)
Operating Temperature -20 °C to +70 °C (-4 °F to +158 °F)
Storage Temperature -20 °C to +70 °C (-4 °F to +158 °F)
EN50575 CPR Cable EuroClass Fire Performance Eca
Environmental Space Universal Low Smoke Zero Halogen (ULSZH)
Water Penetration 24 h

Environmental Test Specifications

Temperature Cycle -20 °C to +70 °C (-4 °F to +158 °F)
Temperature Cycle Test Method IEC 60794-1-2 F1

Packaging and Weights

Cable weight 44 kg/km | 29.567 lb/kft