2160164-1 | L-002-DN-8F-M01WH/AY/D

Base Product: L-DN

  • Available in:
  • Asia
  • Australia/New Zealand
  • EMEA
  • North America

Fiber indoor/outdoor drop cable, FTTH, 2 Fiber, Singlemode G.657.A1, Gel-free, meters jacket marking, White jacket color, Dca flame rating

Find a Partner
Specifications
Finish making your selections or clear them to view relevant specifications.

Product Classification

Regional Availability Asia | Australia/New Zealand | EMEA | North America
Portfolio CommScope®
Product Type Fiber drop cable
Product Series L-DN

General Specifications

Cable Type Drop | Semi-tight buffer
Construction Type Non-armored
Subunit Type Gel-free
Jacket Color White
Jacket Marking Meters
Jacket Marking Method Inkjet
Jacket Marking Text COMMSCOPE GB SMF G657A MACL9/125 S LSZH EN50575 CLASS Dca [Serial NUMBER] [METRE MARK]
Subunit, quantity 1
Fibers per Subunit, quantity 1
Total Fiber Count 2

Dimensions

Cable Length 2000.000 m | 6561.68 ft
Buffer Tube/Subunit Diameter 0.9 mm | 0.035 in
Diameter Over Jacket 4 mm | 0.157 in

Representative Image

Click on image to enlarge.

Material Specifications

Jacket Material Low Smoke Zero Halogen (LSZH)

Mechanical Specifications

Minimum Bend Radius, unloaded 60 mm | 2.362 in
Tensile Load, long term, maximum 600 N | 134.885 lbf
Tensile Load, short term, maximum 1200 N | 269.771 lbf
Compression 20 N/mm | 114.203 lb/in
Compression Test Method IEC 60794-1 E3
Impact 5 N-m | 44.254 in lb
Impact Test Method IEC 60794-1 E4
Strain Test Method IEC 60794-1 E1
Twist 5 cycles
Twist Test Method IEC 60794-1 E7

Optical Specifications

Fiber Type G.657.A1

Environmental Specifications

Installation temperature -30 °C to +60 °C (-22 °F to +140 °F)
Operating Temperature -30 °C to +60 °C (-22 °F to +140 °F)
Storage Temperature -30 °C to +60 °C (-22 °F to +140 °F)
Cable Qualification Standards IEC 60794-1-2
EN50575 CPR Cable EuroClass Fire Performance Dca
EN50575 CPR Cable EuroClass Smoke Rating s1a
EN50575 CPR Cable EuroClass Droplets Rating d0
EN50575 CPR Cable EuroClass Acidity Rating a1
Environmental Space Drop | Ducted | Façade | Indoor/Outdoor | UV resistant for outdoor and Low Smoke Zero Halogen
Jacket UV Resistance UV stabilized
Water Penetration 24 h
Water Penetration Test Method IEC 60794-1 F5

Environmental Test Specifications

Temperature Cycle -30 °C to +60 °C (-22 °F to +140 °F)
Temperature Cycle Test Method IEC 60794-1-2 F1

Packaging and Weights

Cable weight 20 kg/km | 13.439 lb/kft

Regulatory Compliance/Certifications

Agency Classification
ROHS Compliant
CHINA-ROHS Below maximum concentration value
REACH-SVHC Compliant as per SVHC revision on www.commscope.com/ProductCompliance
UK-ROHS Compliant

Product Classification

Regional Availability Asia | Australia/New Zealand | EMEA | North America
Portfolio CommScope®
Product Type Fiber drop cable
Product Series L-DN

General Specifications

Cable Type Drop | Semi-tight buffer
Construction Type Non-armored
Subunit Type Gel-free
Jacket Color White
Jacket Marking Meters
Jacket Marking Method Inkjet
Jacket Marking Text COMMSCOPE GB SMF G657A MACL9/125 S LSZH EN50575 CLASS Dca [Serial NUMBER] [METRE MARK]
Subunit, quantity 1
Fibers per Subunit, quantity 1
Total Fiber Count 2

Dimensions

Cable Length 2000.000 m | 6561.68 ft
Buffer Tube/Subunit Diameter 0.9 mm | 0.035 in
Diameter Over Jacket 4 mm | 0.157 in

Material Specifications

Jacket Material Low Smoke Zero Halogen (LSZH)

Mechanical Specifications

Minimum Bend Radius, unloaded 60 mm | 2.362 in
Tensile Load, long term, maximum 600 N | 134.885 lbf
Tensile Load, short term, maximum 1200 N | 269.771 lbf
Compression 20 N/mm | 114.203 lb/in
Compression Test Method IEC 60794-1 E3
Impact 5 N-m | 44.254 in lb
Impact Test Method IEC 60794-1 E4
Strain Test Method IEC 60794-1 E1
Twist 5 cycles
Twist Test Method IEC 60794-1 E7

Optical Specifications

Fiber Type G.657.A1

Environmental Specifications

Installation temperature -30 °C to +60 °C (-22 °F to +140 °F)
Operating Temperature -30 °C to +60 °C (-22 °F to +140 °F)
Storage Temperature -30 °C to +60 °C (-22 °F to +140 °F)
Cable Qualification Standards IEC 60794-1-2
EN50575 CPR Cable EuroClass Fire Performance Dca
EN50575 CPR Cable EuroClass Smoke Rating s1a
EN50575 CPR Cable EuroClass Droplets Rating d0
EN50575 CPR Cable EuroClass Acidity Rating a1
Environmental Space Drop | Ducted | Façade | Indoor/Outdoor | UV resistant for outdoor and Low Smoke Zero Halogen
Jacket UV Resistance UV stabilized
Water Penetration 24 h
Water Penetration Test Method IEC 60794-1 F5

Environmental Test Specifications

Temperature Cycle -30 °C to +60 °C (-22 °F to +140 °F)
Temperature Cycle Test Method IEC 60794-1-2 F1

Packaging and Weights

Cable weight 20 kg/km | 13.439 lb/kft
Click on image to enlarge.

Regulatory Compliance/Certifications

Agency Classification
ROHS Compliant
CHINA-ROHS Below maximum concentration value
REACH-SVHC Compliant as per SVHC revision on www.commscope.com/ProductCompliance
UK-ROHS Compliant

Product Specification

Product Specification